PHILLIPS TEMRO INC DIVISION OF BUDD CO INC -- 605-3252,605-3253 ZERO-START DIESEL ENGINE STARTING FLUID -- 6850-00D007284
=====================  Product Identification  =====================

Product ID:605-3252,605-3253 ZERO-START DIESEL ENGINE STARTING FLUID
MSDS Date:04/10/1990
FSC:6850
NIIN:00D007284
=== Responsible Party ===
Company Name:PHILLIPS TEMRO INC DIVISION OF BUDD CO INC
Address:9700 W 74TH ST
City:EDEN PRAIRIE
State:MN
ZIP:55344
Country:US
Info Phone Num:800-328-6108/612-941-9700
Emergency Phone Num:800-328-6108/612-941-9700
CAGE:6Y402
=== Contractor Identification ===
Company Name:BALKAMP INC
Address:2601 S HOLT ROAD
Box:City:INDIANAPOLIS
State:IN
ZIP:46241
Country:US
Phone:317-244-7241
CAGE:70842
Company Name:NAPA
Box:UNKNOW
CAGE:0NBN5
Company Name:PHILLIPS TEMRO INC DIVISION OF BUDD CO INC
Address:9700 W 74TH ST
City:EDEN PRAIRIE
State:MN
ZIP:55344
Country:US
CAGE:6Y402

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;96

Ingred Name:ETHYL ETHER (CERCLA); DIETHYL ETHER
CAS:60-29-7
RTECS #:KI5775000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:400 PPM
ACGIH TLV:400PPM/500STEL; 9596
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:N-HEPTANE
CAS:142-82-5
RTECS #:MI7700000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:500 PPM
ACGIH TLV:400 PPM/500STEL;9596

Ingred Name:MINERAL OIL-NAPTHENIC
CAS:64742-13-8
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50(RAT)=1.2G/KG FOR ETHER
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:RESP IRRITATION MAY OCCUR ABOVE
    200PPM.INHAL:INTOXICATION,DROWS,STUPOR & POSSIBLE
    UNCONSCIOUSNESS.SKIN:CRACKING & DRYING OF SKIN IF
    OVEREXPOSED.INGEST:NAUSEA.EYE:IRRIT.
Explanation of Carcinogenicity:PER MSDS:NTP/IARC/OSHA:NO.
Effects of Overexposure:RESPIRATION IRRIT,
    INTOXICATION,DROWSINESS,STUPOR,UNCONSCIOUSNESS,CRACKING/DRYING OF
    SKIN NAUEA,EYE IRRIT.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE BREATHING OR NERVOUS
    DISORDERS.

=======================  First Aid Measures  =======================

First Aid:INHAL:ACUTE INHAL LC50(2.5HRS)=73000PPM(RAT)FOR ETHER.REMOVE
    TO FRESH AIR.SKIN:FLUSH WELL W/WATER.INGEST:DONT INDUCE VOMIT.DRINK
    WATER OR MILK.CALL PHYSICIAN OR POISON CONTROL CENTER
    IMMED.EYE:FLUSH W ELL W/WATER.CONTACT PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:-56F,-49C
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:1.8
Upper Limits:48.0
Extinguishing Media:DRY CHEMICAL, CO2, WATER (FOG OR MIST ONLY),
    ALCOHOL FOAM.
Fire Fighting Procedures:AVOID POSSIBLE ACCUMULATION OF FLAMM VAPORS AT
    LOW LEVELS AS VAPOR IS HEAVIER THAN AIR.SELF-CONTAINED BREATHING
    APPARATUS SHOULD BE WORN WHILE FIGHTING FIRES.
Unusual Fire/Explosion Hazard:AVOID BURSTING OF CYLINDERS.DO NOT STORE
    WHERE TEMPERATURES MAY EXCEED 160F.DO NOT PUNCTURE OR INCINERATE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:KEEP AWAY FROM HEAT/SPARKS/FLAMES.VENTILATE
    AREA.CO2 MAY BE USED AS PRECAUTIONARY VAP BLANKET.SMALL AMOUNTS MAY
    BE FLUSHED W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DONT STORE WHERE TEMPS MAY EXCEED
    160F.DONT STORE NEAR HEAT/FIRE/FLAMES/SPARKS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF TLV IS EXCEEDED WEAR NIOSH APPROVED BREATHING
    DEVICE OR RESPIRATOR.
Ventilation:LOC EXHAUS:ADEQUATE TO MAINTAIN VAPORS @LESS THAN 400
    PPM,ESPECIALLY @FLOOR LEVELS AS VAPS ARE HEAVIER THAN AIR.
Protective Gloves:NITRILE OR IMPERVIOUS
Eye Protection:SAF GLASSES OR GOGG RECOMMENDED
Other Protective Equipment:NITRILE CLOTHING IF THERES POTENTIAL FOR
    PROLONGED CONTACT.
Work Hygienic Practices:FOLLOW STORAGE AND HNDLG PROCEDURES SHOWN
    ABOVE.
Supplemental Safety and Health
ONLY DIFFERENCE IS IN "HOOK-UP"FITTING SIZE. FLASH PT/FLAMM
    LIMITS/BOILING PT FOR DIETHYL ETHER.

==================  Physical/Chemical Properties  ==================

HCC:G2
Boiling Pt:=34.4C, 94.F
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:150 PSIG
Vapor Density:2.5
Spec Gravity:0.70
pH:NP
Viscosity:NP
Evaporation Rate & Reference:0.60, BUTYL ACETATE=1
Solubility in Water:6%, MODERATE
Appearance and Odor:PALE YELLOW TO CLEAR LIQUID, STRONG ETHEREAL
    ODOR.EVAPORATES QUICKLY, CYLINDER
Percent Volatiles by Volume:100
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:GENERALLY STABLE.EXPLOSIVE PEROXIDES MAY
    FORM BY EVAPORATION,PROCESS FAVORED BY EXPOSURE TO AIR & LIGHT.
Hazardous Decomposition Products:CARBON MONOXIDE AMY FORM ON
    COMBUSTION.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF PROMPTLY IN SEALED METAL CNTNRS IAW
    ALL LOCAL, STATE AND FEDERAL REGULATIONS.AVOID CONTAMINATION OF
    GROUNDWATER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.